UAA researcher senses a solution to pipeline corrosion

by Joe Selmont  |   

UAA mechanical engineering professor Oleg Shiryayev holding a sensor
Every little pipe on the North Slope is a potential hazard, particularly when it comes to the problem of corrosion. UAA mechanical engineering professor Oleg Shiryayev has begun developing a solution. Using magnetostrictive materials, magnetic flux and fiber optic sensors, he has piloted a system that could save money and improve safety in the oil and gas industry. (Photo by Ted Kincaid/UAA College of Engineering)

On the North Slope there are thousands of small pipes that ultimately come together to feed into the big one — the Trans-èƵ Pipeline. Each of those pipes are a potential hazard, especially as they experience the effects of air, water and chemistry over long periods of time.

Even in the cold of the Arctic, pipes will eventually succumb to corrosion — the natural chemical process that transforms refined metals into oxides. Rust, for example, occurs when iron and oxygen form a chemical bond. If technicians responsible for monitoring those pipes don’t catch corrosion and other forms of degradation before it’s too late, then a pipe could burst, resulting in a problem with serious environmental, financial and public relations consequences. 

That’s where Oleg Shiryayev, Ph.D., assistant professor of mechanical engineering in UAA’s College of Engineering, comes in. 

“The problem with flow lines, or the small pipes that connect from the wells to the first processing facilities, is that they do not regularly get the same protection as the big boy, the Trans-èƵ Pipeline,” said Shiryayev. “Simply put, there are too many of them. And for that same reason, it is very difficult to adequately monitor all of them.”

To keep an eye on the integrity of flow lines, the current process requires a team of technicians to physically walk around the pipes and inspect them for damage using ultrasound and additional measuring tools. While this method is reasonably effective, Shiryayev points out  it is highly inefficient. Plus, it is difficult to access some pipes once they have been installed. 

To make matters worse, flow lines and other small pipes are rarely equipped with the launching and retrieval mechanisms that are required to use one of the industry’s most efficient monitoring tools — pipeline inspection gauges, or PIGs. For the larger pipes, and particularly for the 800-mile long Trans-èƵ Pipeline, PIGs enter at one location, get caught up in the flow and then exit dozens or hundreds of miles downstream. During their wild rides, the PIGs use a variety of sensors to capture important data about the integrity of the pipeline. 

“But since we cannot monitor flow lines from within using PIGs, we have to monitor them from the outside,” said Shiryayev. “And my project demonstrates the feasibility of using fiber optics and magnetism to accomplish precisely that.”

The details of Shiryayev’s project get a little technical — so buckle up. 

Shiryayev’s core concept is to use a combination of fiber optic strain sensors and a magnetostrictive material, such as an alloy called terfenol-d, to monitor the magnetic flux that leaks out of a pipe as its walls becomes thinner due to corrosion or other forms of damage. Magnetostrictive materials are any substance that can be mechanically deformed by the presence of an external magnetic field. Magnetic flux is a measurement of the total magnetic field passing through a given area. 

To put this another way, Shiryayev’s fiber optic sensors report any deformities that happen to the magnetostrictive materials. Those deformities can only happen if a pipe is damaged enough that its magnetic field is leaking. For an undamaged pipe, its magnetic field remains almost entirely inside the pipe wall. If the terfenol-d (or other magnetostrictive material) is stretched even a tiny bit, the fiber optic strain sensors will alert technicians, letting them know that it’s time to give that section of pipe a closer inspection, and maybe even replace it. 

The concept of using magnetic flux leakage to measure the integrity of pipes is not new. In fact, it is one of the main tools used by PIGs when they travel down larger pipelines. The novelty of Shiryayev’s contribution to the field is the combination of fiber optic strain sensors and magnetostrictive materials. Practically speaking, this could allow for deployment of the system over long stretches of difficult-to-access pipes.

“The main advantage of this kind of monitoring regime is that it is much more economical to achieve higher levels of safety,” said Shiryayev. “Companies could have round-the-clock monitoring of their flow lines, without needing to constantly send crews out for inspection.”

Shiryayev’s research is still in the early stages. He has completed a proof-of-concept study with funding from ConocoPhillips èƵ. He hopes that he and UAA will patent the design sometime soon and obtain funding for further development. In the future, he imagines that this research could have significant commercial appeal. 

“It has the potential to make oil and gas extraction safer and more cost effective,” said Shiryayev. “What’s not to like?”

"UAA researcher senses a solution to pipeline corrosion" is licensed under a .